Polacel XL cooling towers

The Polacel cross flow cooling tower is quiet and economical, and has a high cooling capacity. The modular system can be easily adjusted to suit cooling requirements and the space available.
The cooling towers have optimal performance and run problem-free. The considerable savings in water usage (95%+), and the exceptionally low noise level make the economical crossflow cooling towers the best choice for both man and the environment.
| Type |
Wet surface (m2) |
Q min (m3/h) |
Q max (m3/h) |
Dimensions |
Weight |
Number of engines |
| L (mm) |
B (mm) |
H (mm) |
empty (kg) |
operational (kg) |
| XL2.320-600 |
3,84 |
30 |
211 |
5.190 |
3.440 |
4.110 |
5.920 |
7.620 |
1 |
| XL2.320-900 |
5,76 |
46 |
317 |
5.190 |
3.440 |
4.110 |
6.225 |
7.925 |
1 |
| XL4.440-900 |
16,10 |
128 |
805 |
6.390 |
4.410 |
7.371 |
7.500 |
11.250 |
1 |
| XL4.520-900 |
18,50 |
130 |
950 |
6.390 |
5.200 |
7.371 |
8.000 |
12.500 |
1 |
- All data is for information only. Please contact Polacel for certified data.
- All types are available with different air speeds.
- Polacel has extensive specifications for all cooling towers listed above.
| XL cooling tower
|
 |
| <>XL cooling tower
|
 |
|
|
Structural qualities
The advanced design engineering has also resulted in a number of special structural advantages:
- Only a minimum number of support points are necessary as a result of the self-supporting foundations and the high internal rigidity.
- Where possible, fully portable and installed ready to go.
- The Polacel frost-proof polyester water pan can withstand sub-zero temperatures. Essential for free-cooling applications.
- Due to their low profile, cross flow cooling towers present fewer aesthetic problems.
- The expandable modular system has virtually no limitations in terms of shape and size.
- All structural design principles are analysed and tested in advance using dynamic calculations and computer studies.
Durable and reliable
Polacel designs and manufactures cooling towers that have a long life and require a minimum of maintenance. This performance is achieved by a careful choice of materials - stainless steel combined with glass fibre reinforced polyester and plastics - the exceptionally sound design and the considerable experience of our engineers.
'Cheap and cheerful' solutions such as fans with a V-belt drive, or painted panels, are avoided. The result is a cooling tower that is low maintenance, economical and able to deliver a consistently high quality, problem-free performance.
|
|