CMDR cooling towers                                                                                                                

The Polacel CMDR cooling tower concept can process large quanti­ties of water and it has a substan­tial cooling capacity. The modular CMDR systems are easy to adjust to cooling require­ments and the available space, whether they are used singly or in series.

The cooling perfor­mance of these cooling towers is optimal and operation is problem free. With a 95%+ saving in water, the efficient CMDR systems are the best choice for man and his environ­ment.

Cooling needs: demand = supply

The cooling water tem­pera­tures (inlet and outlet), the wet bulb tem­pera­ture, noise and the water load are the four most important factors in the selection of a cooling tower. Polacel makes an inventory of the require­ments together with the client and uses this inventory as the basis of the design for a suitable solution.

There are standard solutions in the modular CMDR system for virtually any capacity require­ment. Polacel engineers make custo­mized changes to meet special require­ments.

Fast and flexible con­struc­tion

Polacel can build these cooling towers in a very limited time frame thanks to the struc­tural quality and the flexible appli­cation options offered by the modular CMDR concept.

For example, the CMDR system can be assembled prior to a shutdown (along­side the existing operating cooling tower) and then be hoisted as a complete unit and installed on the existing water basin during the shutdown. This is why the construc­tion time of a Polacel cooling tower always fits into your schedule.

Type Wet sur­face (m2) Q min (m3/h) Q max (m3/h) Dimensions Weight Drive type
L (mm) B (mm) H (mm) empty (kg) ope­ra­tio­nal (kg)
CMDR 135 13 91 455 3.720 3.720 4.890 2.870 6.320 geared motor
CMDR 160 16 112 560 4.380 3.720 5.275 3.420 7.500 geared motor
CMDR 180 18 126 576 4.980 3.720 5.325 3.420 7.500 geared motor
CMDR 210 21 147 735 4.980 4.380 5.455 4.180 9.740 geared motor
CMDR 240 24 168 840 4.980 4.980 5.925 4.850 11.260 geared motor
CMDR 300 30 210 1.050 6.240 4.980 6.105 6.280 14.490 geared motor
CMDR 380 38 266 1.216 6.240 6.240 6.235 8.060 22.650 geared motor
CMDR 460 46 322 1.472 7.440 6.240 6.385 9.650 27.420 geared motor
CMDR 540 54 378 1.728 7.440 7.440 6.785 11.740 33.100 geared motor
CMDR 630 63 441 2.016 8.640 7.440 6.785 13.310 38.070 geared motor
CMDR 740 74 518 2.368 7.440 7.440 6.785 15.630 44.700 geared motor
CMDR 840 84               geared motor
CMDR 960 96               geared motor
CMDR1200 120               geared motor

 

  • All data is for information only. Please contact Polacel for certified data.
  • All types are available with different air speeds and different fills.
  • Polacel has extensive specifications for all cooling towers listed above.